§ 13-44. Development standards  


Latest version.
  • Table 13-44 identifies development standards for the various commercial zones. See also Article 9, General Site Improvement Standards of this chapter for additional requirements.

    TABLE 13-44
    COMMERCIAL PROPERTY DEVELOPMENT STANDARDS

    DEVELOPMENT STANDARDS P AP CL C1 C2 C1-S TC
    Minimum Lot Area for newly created lots 6,000 square feet 12,000 square feet 5 acres See Master Plan
    Minimum Lot Width for newly subdivided lots 120 feet
    Note: All newly subdivided lots shall have frontage on a dedicated street equal to, or in excess of, the required minimum lot width.
    120 feet
    Note: All newly subdivided lots shall have frontage on a dedicated street equal to, or in excess of, the required minimum lot width.
    None
    Minimum Lot Width Interior Lot: 50 feet
    Corner Lot: 60 feet
    60 feet None
    Maximum Floor Area Ratio Refer to CHAPTER V, ARTICLE 8, FLOOR AREA RATIOS.
    Maximum Building/Structure Height 2 stories/30 feet None
    SETBACKS FOR MAIN BUILDINGS AND ACCESSORY BUILDINGS AND STRUCTURES (Minimum distances given, unless otherwise noted. All setbacks from streets are measured from the ultimate property line shown on the master plan of highways.)
    Front 20 feet
    Side (Interior) 15 feet on one side and 0 feet on the other side.
    Exception: If the side property line is adjacent to a residential zone, all buildings shall maintain a side setback from the residential property line of 2 times the building height at all locations.
    None
    Rear (Interior) 0 feet
    Exception: If the rear property line is adjacent to a residential zone, all buildings shall maintain a rear setback from the residential property line of 2 times the building height at all locations.
    None
    Side or Rear abutting a public street 20 feet for secondary, primary or major streets per the master plan of highways.
    15 feet for all other streets.
    20 feet — see also subsections 13-45(f) and (g).
    PROJECTIONS (Maximum depth of projections given)
    Roof or Eaves overhang; Awning 2 feet 6 inches into required side setback.
    5 feet into required front or rear setback.
    None
    Open, unenclosed Stairways. 2 feet 6 inches into required setback area. None
    PARKING (See CHAPTER VI)

     

    DEVELOPMENT STANDARDS P AP CL C1 C2 C1-S TC
    LANDSCAPING (See CHAPTER VII)
    SIGNS (See CHAPTER VIII)
    ADDITIONAL DEVELOPMENT STANDARDS
    Planned Signing Program Not required Required (see CHAPTER VIII, SIGNS)
    Master Plan Not required Required: The final review authority is the Planning Commission (see CHAPTER III, PLANNING APPLICATIONS)
    Uses Underroof All uses shall be conducted underroof except as allowed by a minor conditional use permit or as permitted elsewhere in this Zoning Code. Exception: Sidewalk and parking lot sales may be allowed for a maximum of 4 sales per fiscal year with a maximum length of 3 days per sale and subject to obtaining a business permit.
    Outdoor Storage (incidental to the main use) Permitted when: Storage does not interfere with required parking or vehicular access; storage is not in required setback area abutting a public right-of-way; storage does not decrease required landscaping; storage is completely screened from view from street or adjacent properties; storage complies with all applicable codes and regulations including, but not limited to, the Uniform Fire Code. Shipping containers shall also comply with setback requirements for structures, floor area ratio standards, and parking requirements. A permanent foundation shall be required for shipping containers. Storage not meeting these criteria requires approval of a minor conditional use permit.

     

(Ord. No. 97-11, § 2, 5-5-97; Ord. No. 98-5, § 11, 3-2-98; Ord. No. 02-4, § 1d, 3-18-02; Ord. No. 02-9, § 1c, 7-1-02 ; Ord. No. 05-2, § 1g., 2-22-05 )